CH01
Indoor temperature sensor error
MEDIUMRoom temperature sensor malfunction. Check sensor wiring and replace if faulty.
Action Required: Schedule service within 1-2 days
CH02
Indoor coil sensor error
MEDIUMEvaporator coil temperature sensor fault. Professional sensor replacement required.
Action Required: Schedule service within 1-2 days
CH03
Outdoor coil sensor error
MEDIUMCondenser coil temperature sensor malfunction. Replace outdoor coil sensor.
Action Required: Schedule service within 1-2 days
CH04
Outdoor temperature sensor error
MEDIUMOutdoor ambient temperature sensor fault. Check outdoor sensor connections.
Action Required: Schedule service within 1-2 days
CH05
Communication error
URGENTIndoor/outdoor communication failure. Check control cable and connections.
Action Required: Contact professional technician immediately
CH06
Indoor fan motor error
URGENTIndoor blower motor malfunction. Check motor operation and electrical supply.
Action Required: Contact professional technician immediately
CH07
Outdoor fan motor error
URGENTOutdoor fan motor fault. Inspect outdoor fan and motor connections.
Action Required: Contact professional technician immediately
CH08
Compressor error
URGENTCompressor malfunction or protection activated. Professional compressor diagnosis required.
Action Required: Contact professional technician immediately
CH09
High pressure protection
URGENTHigh refrigerant pressure detected. Check system for blockages or overcharge.
Action Required: Contact professional technician immediately
CH10
Low pressure protection
URGENTLow refrigerant pressure detected. Check for refrigerant leaks and recharge system.
Action Required: Contact professional technician immediately
CH11
Discharge temperature sensor error
MEDIUMCompressor discharge temperature sensor fault. Professional replacement required.
Action Required: Schedule service within 1-2 days
CH12
Suction temperature sensor error
MEDIUMCompressor suction temperature sensor malfunction. Check sensor and connections.
Action Required: Schedule service within 1-2 days
CH13
Liquid line sensor error
MEDIUMLiquid line temperature sensor fault. Professional sensor replacement needed.
Action Required: Schedule service within 1-2 days
CH14
Gas line sensor error
MEDIUMGas line temperature sensor malfunction. Check sensor and connections.
Action Required: Schedule service within 1-2 days
CH15
Heat exchanger sensor error
MEDIUMHeat exchanger temperature sensor fault. Professional sensor replacement required.
Action Required: Schedule service within 1-2 days
CH16
Oil temperature sensor error
MEDIUMCompressor oil temperature sensor malfunction. Professional diagnosis required.
Action Required: Schedule service within 1-2 days
CH17
Current sensor error
MEDIUMCurrent sensor fault. Professional sensor replacement needed.
Action Required: Schedule service within 1-2 days
CH18
Voltage sensor error
MEDIUMVoltage sensor malfunction. Check electrical connections and sensor.
Action Required: Schedule service within 1-2 days
CH19
Position sensor error
MEDIUMMotor position sensor fault. Professional sensor replacement required.
Action Required: Schedule service within 1-2 days
CH20
Speed sensor error
MEDIUMMotor speed sensor malfunction. Check sensor and motor connections.
Action Required: Schedule service within 1-2 days
HS01
High pressure alarm
URGENTSystem high pressure alarm activated. Check refrigerant charge and condenser.
Action Required: Contact professional technician immediately
HS02
High temperature alarm
URGENTHigh temperature protection activated. Check system operation and ventilation.
Action Required: Contact professional technician immediately
HS03
Compressor overload
URGENTCompressor overload protection triggered. Professional compressor inspection required.
Action Required: Contact professional technician immediately
Motor overload protection activated. Check motor condition and electrical supply.
Action Required: Contact professional technician immediately
HS05
Inverter overload
URGENTInverter overload protection triggered. Professional inverter diagnosis required.
Action Required: Contact professional technician immediately
HS06
High voltage protection
MEDIUMSupply voltage too high. Check electrical supply and voltage regulation.
Action Required: Schedule service within 1-2 days
HS07
High current protection
URGENTElectrical current too high. Check wiring and electrical connections.
Action Required: Contact professional technician immediately
HS08
High frequency protection
MEDIUMOperating frequency too high. Check system settings and operation.
Action Required: Schedule service within 1-2 days
HS09
High superheat alarm
MEDIUMSuperheat too high. Check expansion valve and refrigerant charge.
Action Required: Schedule service within 1-2 days
HS10
High subcooling alarm
MEDIUMSubcooling too high. Check refrigerant overcharge and condenser operation.
Action Required: Schedule service within 1-2 days
LS01
Low pressure alarm
URGENTSystem low pressure alarm activated. Check for refrigerant leaks.
Action Required: Contact professional technician immediately
LS02
Low temperature alarm
MEDIUMLow temperature protection activated. Check system operation and settings.
Action Required: Schedule service within 1-2 days
LS03
Low voltage protection
MEDIUMSupply voltage too low. Check electrical connections and utility supply.
Action Required: Schedule service within 1-2 days
LS04
Low current alarm
MEDIUMElectrical current too low. Check motor and electrical connections.
Action Required: Schedule service within 1-2 days
LS05
Low frequency protection
MEDIUMOperating frequency too low. Check system settings and operation.
Action Required: Schedule service within 1-2 days
LS06
Low superheat alarm
MEDIUMSuperheat too low. Check expansion valve and refrigerant flow.
Action Required: Schedule service within 1-2 days
LS07
Low subcooling alarm
MEDIUMSubcooling too low. Check refrigerant charge and condenser performance.
Action Required: Schedule service within 1-2 days
LS08
Low oil level alarm
URGENTCompressor oil level low. Professional oil level check and refill needed.
Action Required: Contact professional technician immediately
LS09
Low oil pressure alarm
URGENTOil pressure too low. Professional oil system diagnosis required.
Action Required: Contact professional technician immediately
LS10
Low airflow alarm
MEDIUMInsufficient airflow detected. Check filters and ductwork.
Action Required: Schedule service within 1-2 days
DF01
Defrost sensor error
MEDIUMDefrost sensor malfunction. Check sensor and defrost operation.
Action Required: Schedule service within 1-2 days
DF02
Defrost cycle error
MEDIUMDefrost cycle malfunction. Professional defrost system diagnosis required.
Action Required: Schedule service within 1-2 days
Air filter requires cleaning or replacement. Clean or replace filters.
Action Required: Monitor and perform basic maintenance
Condensate drain system fault. Check drain pan and drainage.
Action Required: Schedule service within 1-2 days
DF05
Frost accumulation
MEDIUMExcessive frost accumulation. Check airflow and defrost operation.
Action Required: Schedule service within 1-2 days